Air Pollution Control

Industrial Induced Draft Fan

In this air pollution control installation example, we designed and delivered a heavy-duty fan for an OEM who designs and manufactures thermal oxidizers. This backward-curved induced draft fan is an arrangement 8 direct-coupled drive with a flexible coupling.

Air pollution control requires heavy-duty construction with materials like special alloys, coatings, and accessories for processing particulates in the polluted air stream. This installation included extended lubrication lines for ease of maintenance.

For more information, read about backward curved and induced draft fans.

If you have a similar project, call 715-365-3267 to talk with our application engineers.
Air Pollution Control
Performance: 22,000 cfm airflow @ 26" wg static pressure @ 0.07lb/ft^3 inlet air density
Product Type
BCHX (backward curved)
Size
451 (45.1” diameter wheel)
Class
5
Arrangement
8 (direct-coupled drive)
Horsepower
125 HP
Max Design Temperature
150°F
AirPro Fan P.O. Box 543, Rhinelander, WI 54501 (715) 365-FANS (3267) airprofan.com